Review these requirements before you set up or use a Morpho Desktop UV printer. You need a stable, well-ventilated indoor workspace with room for the printer, a laptop, and day-to-day use.
| Item | Requirement |
|---|---|
| Use | Indoor only |
| Ambient temperature | 20–30°C (68–86°F) |
| Relative humidity | 35–60% RH, non-condensing |
Keep the printer away from dust, moisture, vibration, direct sunlight, water, and heat. Keep flammable materials and solvents such as acetone, alcohol, and gasoline away from the printer. Keep pets away.
| Item | Requirement |
|---|---|
| Printer dimensions | 660 × 430 × 390 mm |
| Printer weight | About 32 kg, excluding accessories |
| Recommended workbench | 1.3 × 1.3 m, enough for one printer and one laptop |
| Front / rear clearance | 40 cm |
| Left / right clearance | 30 cm |
Due to the printer weight, two-person handling is recommended during relocation.
Place the printer on a flat, stable workbench before you connect power. The printer must sit level and must not rock.
Keep this clearance around the printer so the Printbed can move, the lid or door can open, and you can load materials, connect cables, and do maintenance.
Do not let the Printbed extend beyond the workbench. Keep the Power/standby button and DC IN easy to reach. Keep at least 20 cm between the wireless transmitter and your body.
If the workbench has casters, lock them before use.
Use only the supplied adapter and power cord with a properly earthed indoor outlet.
| Item | Requirement |
|---|---|
| Adapter input | 100–240 V AC, 50/60 Hz, 2.5 A |
| Adapter output | 24.0 V DC, 6.0 A, 144.0 W |
| Printer connector | DC IN |
| Power control | Power/standby button |
| Network connector | LAN (Ethernet) |
Keep the cable where it cannot be pinched, crushed, or walked on. Do not plug in, unplug, or operate the printer with wet hands.
The printer emits UV light during printing.
This product is classified as a Class 1 CONSUMER LASER PRODUCT.
| Item | Specification |
|---|---|
| Classification | Class 1 CONSUMER LASER PRODUCT |
| Standards | IEC 60825-1:2014, EN 60825-1:2014+A11:2021, EN 50689:2021 |
| Wavelength | 650–660 nm |
| Maximum output power | 0.39 mW |
Use only Morpho-approved ink and cleaning products. Read the SDS before handling them.
Handling
Storage and disposal
Spill
Exposure
| Contact | What to do |
|---|---|
| Skin | Wash with soap and water for at least 15 minutes. Seek medical help if irritation continues. |
| Eyes | Rinse with clean water for at least 15 minutes, including under the eyelids. Get medical help immediately. |
| Swallowed | Do not induce vomiting. Get medical help or contact a poison control center. |
The printer contains a 3 V CR1220 coin cell for the real-time clock. Do not replace it yourself.
Keep used batteries away from children. Do not put them in household trash or incinerate them. Do not recharge, disassemble, or heat the battery above 70°C (158°F). If a battery is swallowed, seek medical help immediately.
Before you start a job, confirm that the workspace, clearance, and closed-cover conditions above are met.
If the printer smokes, smells like burning, makes unusual noises, or behaves abnormally, stop the job and unplug the printer if it is safe. Do not use it. Contact Morpho Support.
Follow the instructions for the part you are servicing. Use only the specified tools and cleaning materials.
We hope this guide has been helpful. If you have any questions or need further assistance, our support team is here to help.