Print-to-Camera Calibration establishes the mapping between the printer coordinate system and the top-left camera. This allows the printer to convert positions detected by the camera into their corresponding physical positions on the printbed.
If this mapping is inaccurate, the printer may calculate the target print position incorrectly. As a result, the printed pattern may not appear where it is expected on the material.
By completing Print-to-Camera Calibration, the printer can more accurately convert visual recognition results into actual print positions and keep the printed result aligned with the expected location.
Tip: Print-to-Camera Calibration is the recommended calibration for most print placement offsets.
| Before calibration | After calibration |
|---|---|
![]() |
![]() |
Print-to-Camera Calibration is required in these situations:
Calibration can start when the following conditions are met:

You can open Position Calibration in Morpho Studio or on the printer screen.
| 1. Open Devices | 2. Open Maintenance | 3. Open Position Calibration |
|---|---|---|
![]() |
![]() |
![]() |
| 1. Open Maintenance | 2. Open Position Calibration |
|---|---|
![]() |
![]() |
| Calibration in progress | Calibration completed |
|---|---|
![]() |
![]() |
If the printed pattern is incomplete, unclear, or visibly abnormal, the calibration calculation may fail. Check the printbed and try again.
If the printer detects a camera alignment issue, it displays Further Assistance Is Needed.
Select Set Up Calibration to continue with Stereo Camera Calibration.
.png)
After Stereo Camera Calibration is complete:
If the screen displays a retry prompt, select Retry once.

Warning: If the same error appears again after retrying, stop the procedure and contact Technical Support.
After Print-to-Camera Calibration, clean the printbed and run Position Accuracy Test Print.
| Morpho Studio | Printer screen |
|---|---|
![]() |
![]() |
At each corner, compare the outermost line of the printed frame with the inner corner of the corresponding L-shaped mark.
The printbed marks may have screen-printing variation. The result is considered normal when the outermost printed line is within 0.5 mm of the corresponding inner corner.

If the test fails:
After three consecutive calibration-and-test cycles fail to resolve the offset, continue with Origin Calibration.